LPS Designer Pro

Risk assessment. Design. Protection.
Lightning

Risk assessment & Design in compliance with IEC 62305:2024 & NF C 17-102:2011

1 Tool, 2 Functions

Function 1

Lightning risk calculation

IEC 62305:2024 Expert workspace: structured zone, system and line input, controlled server-side calculation and pre-sizing. Closed selections from the transcribed catalogue need no added proof; every applicability decision or applied measure requires a rationale and a declared documentary reference retained in the dossier but not verified.

  • IEC 62305:2024
  • NF C 17-102:2011
  • Custom-header PDF when a logo is supplied
  • Professional report
  • Manual LPL for pre-sizing
  • Multi-zone & multi-bldg.
Function 2

2D/3D Design Studio

Position your lightning rods on plan or satellite view. Visualise ESE protection radii, choose the method (rolling sphere, mesh cage, angle) and export the full nomenclature.

  • ESE & rolling sphere
  • Mesh cage
  • Plan/satellite import
  • Auto nomenclature
  • 2D & 3D view
  • PDF/DXF export
GRATUIT

🆓 Free

Property Owners & Individuals

Free assessment for homes, offices or unoccupied buildings under 30 m, with no registration.

from €49/month incl. VAT

🟢 Initial

Occasional Installer

FD C 17-108 analysis, branded PDF and studies of standard structures.

Discover
from €79/month incl. VAT

⚡ Pro

Professional Installer & Design Office

NF C 17-102:2011 + IEC 62305:2024, service lines and multi-building sites within the declared scope.

Discover
from €129/month incl. VAT

💎 Expert

Engineering Bureau & Lightning Expert

NF C 17-102:2011 + IEC 62305:2024, multi-zone from declared inputs, custom-header PDF and included 2D/3D Studio.

Discover
🎨 Studiofrom €89/month incl. VATExpert / standalone

Graphical design tool for your lightning protection installations — on satellite map, DXF or PDF plan.

🗺️ Satellite + DXF + PDF plan import⚡ ESE / Rolling sphere / Mesh method🔲 2D Studio included with Expert or standalone🧊 3D Studio included with Expert or standalone📄 A4 landscape PDF plan export + BOM🏷️ White-label BOM (Studio / Expert)📦 LPS France BOM (Ellips, Paraton@ir®, Compt@ir®)🌍 FR / EN / ES / PT interface
See pricing
See full pricing

From free consultation to complete professional design!

Protection methods available by module

⚡
ESE
NF C 17-102:2011

Early Streamer Emitter lightning rod — extended protection radius per Δt and LPL. LPS France technology.

🌐
Rolling Sphere
IEC 62305:2024

Fundamental electro-geometric model (EGM). Reference for all complex structures.

🔲
Mesh Cage
IEC 62305:2024

Surface application of EGM model. Roof protection via continuous conductive mesh.

📐
Protection Angle
IEC 62305:2024

Geometric simplification of rolling sphere for simple vertical rods (Franklin type).

Normative references

IEC 62305:2024
NF C 17-102:2011
IEC 62793:2020
IEC 60364-4-44
EN 50310
IEC 61643-11
Developed by

LPS France

French manufacturer of ESE lightning rods for over 25 years. Complete ESE range, connected maintenance and earthing accessories.

⚡ ESE Lightning Rods

8 models in compliance with NF C 17-102:2011 — 4 advance times (10 to 60µs) in standard or communicating version.

Ellips
Ellips 1.0 — 10µsEllips 1.2 — 25µsEllips 1.3 — 45µsEllips 1.4 — 60µs
PARATON@IR® — Contact@ir® Ready
Paraton@ir® 10 — 10µsParaton@ir® 25 — 25µsParaton@ir® 45 — 45µsParaton@ir® 60 — 60µs
View range
📡 Contact@ir® System

Connected maintenance for ESE installations. Remote verification, real-time alerts, normative compliance without accessing the lightning rod.

›
Contact@ir® + Dongl@ir®— Radio frequency — no network needed
›
Contact@ir® + Rout@ir®— IoT — internet connected
›
Contact@ir® MD— Mobile data — standalone
Learn more
🌱 Earthing Accessories

Complete range of earthing accessories compliant with IEC 62305:2024 — conductors, connectors, inspection chambers, soil improver.

Lightning stroke counterDisconnect terminalBranch connectionTinned copper conductor 30×2 mmInspection manholeSoil improverCopper-plated steel rodProtective sheath
View accessories
🏗️ Building Kits

Ready-to-use standard installations — ESE + conductors + earthing. For common structures without a specific study.

Detached houseHouse with patioBuilding < 30mBuilding < 60mGuyed pylonTelecom towerFactoryDanger zone
View kits

Frequently Asked Questions

Everything you need to know about lightning protection

📄
Technical note — Determining Nsg
Version 3.0 — Nsg, Ng and Nt paths aligned with IEC 62305:2024, Annex A.1

LPS Platform — LPS France | LPS Manager | Strike Radar | AtmoGuard | Sky Sentinel